美国PerkinElmer(PE)货号:N9303236 产品名称:GC耗材 H2 24 Carrier Gas Generator PM Kit(H2 24载气发生器维护套件/)/Minor Accessory H2 24 Carrier Gas Generator PM Kit
-
美国PerkinElmer(PE)货号:N9303235 产品名称:GC耗材 H2 Carrier Gas Generator PM Kit(H2载气发生器维护套件/)/Minor Accessory H2 Carrier Gas Generator PM Kit
N9303235 | 见详情
-
美国PerkinElmer(PE)货号:N9303239 产品名称:GC耗材 24 Month H2 Carrier Gas Gen PM Kit H(24月H2载气生成PM套件H/)/Minor Accessory 24 Month H2 Carrier Gas Gen PM Kit H
N9303239 | 见详情
-
美国PerkinElmer(PE)货号:N9303238 产品名称:GC耗材 6 Month H2 Carrier Gas Gen PM Kit H(6个月氢气载气发生器维护套件H/)/Minor Accessory 6 Month H2 Carrier Gas Gen PM Kit H
N9303238 | 见详情
-
美国PerkinElmer(PE)货号:N9303201 产品名称:GC耗材 H2 Carrier Gas Generator, 160 cc/min(H2运载气体发生器,160 cc/min/氮气发生器)/Minor Accessory H2 Carrier Gas Generator, 160 cc/min
N9303201 | 见详情
-
美国PerkinElmer(PE)货号:N9303237 产品名称:GC耗材 H2 Desiccant PM Kit(H2干燥剂PM套件/)/Minor Accessory H2 Desiccant PM Kit
N9303237 | 见详情
-
美国PerkinElmer(PE)货号:N9303202 产品名称:GC耗材 H2 Generator 250 mL/min >99.9999%(氢气发生器/)/Minor Accessory H2 Generator 250 mL/min >99.9999%
N9303202 | 见详情
-
美国PerkinElmer(PE)货号:N9308581 产品名称:GC耗材 NM-H2 Plus Generator Model, 100 mL/min(NM-H2 Plus 发生器模块/氢气发生器)/Minor Accessory NM-H2 Plus Generator Model, 100 mL/min
N9308581 | 见详情
GC耗材 H2 24载气发生器维护套件
基本信息
产品特性
应用领域
产品优势
应用案例
您正在浏览的产品:美国PerkinElmer(PE)货号:N9303236 产品名称:GC耗材 H2 24 Carrier Gas Generator PM Kit(H2 24载气发生器维护套件/)
本公司销售的所有产品仅供实验科研使用,不用于人体及临床诊断。
GB/T 30431-2020 《实验室气相色谱仪》
适用于实验室气相色谱仪的性能测试与维护,包含载气系统(如氢气发生器)的维护要求。
规范仪器基线稳定性、载气流速精度、检测器灵敏度等参数,维护操作需符合附录A中载气系统维护流程。
氢气纯度要求≥99.999%,载气流速波动范围±1%,系统泄漏率≤1×10-9 mL/s。
需定期使用标准气体(如氮中甲烷)验证检测器性能,校准频率至少每季度一次。
维护套件更换时需关闭电源、排空气路,更换后需进行气密性测试与流速校准。
氢气发生器维护涉及高压部件,需由持证人员操作,并记录维护日期与参数。
GB/T 27417-2017 《合格评定 化学分析方法确认和验证指南》
适用于气相色谱分析方法的验证,涵盖载气系统维护后的方法重现性确认。
要求通过重复性实验(RSD≤5%)与线性范围验证(R²≥0.995)确认维护后系统可靠性。
维护后需重新进行方法检出限(LOD)与定量限(LOQ)验证。
GB/T 32465-2015 《化学气相沉积(CVD)气相色谱-质谱联用仪维护方法》
涉及氢气发生器维护对质谱真空系统的兼容性要求。
维护后需检测质谱真空度(≤5×10-5 Pa)并排除载气杂质干扰。