ASTM D5501-12-校准标准3:3组分介绍:

中文名称:ASTM D5501-12-校准标准3:3组分
英文名称:ASTM D5501-12 - Calibartion Standard 3: 3 components: Methanol [CAS:67-56-1] 0.3% (w/w) ; n-Heptane [CAS:142-82-5] 10% (w/w) ; Ethanol [CAS:64-17-5] 75% (w/w) in Iso-octane
Validity:24;ISO 17034\ISO 17025:Yes;

您正在浏览的产品:ASTM D5501-12-校准标准3:3组分

手机版:ASTM D5501-12-校准标准3:3组分

本公司销售的所有产品仅供实验科研使用,不用于人体及临床诊断。

标准名称

ASTM D5501-12 标准试验方法(汽油中特定3组分测定)

适用范围

适用于汽油中苯、甲苯和甲基叔丁基醚(MTBE)的定量分析,检测浓度范围0.1%-40%(体积分数)。

核心检测方法

气相色谱法(GC)结合火焰离子化检测器(FID),采用内标法定量。

检出限与定量限

苯:检出限0.02%、定量限0.05%;甲苯:检出限0.03%、定量限0.08%;MTBE:检出限0.05%、定量限0.10%。

质控样品要求

每批次检测需包含平行样(RSD≤5%)和加标回收率(85%-115%),使用有证标准物质校准系统。

关键实验步骤

1. 样品前处理(溶剂稀释)
2. 色谱柱选择(极性毛细管柱)
3. 程序升温设置(40℃-200℃梯度)
4. 内标物峰面积比校正。

特别说明

1. 需严格控温避免轻组分损失
2. 含氧化合物需单独验证分离度
3. 高浓度样品需梯度稀释后复测。