• 欢迎来到萘析商城
环己酮_108-94-1,环己酮
图片仅供参考,具体产品以实物为准!

环己酮

BW901052 {{goodObj.price > 0 ? '¥' + goodObj.price : '咨询'}} ¥{{goodObj.sell_price || 0}} 咨询 108-94-1 0.5mL {{goodObj.date}} 秦境 {{item.norm}} 99.5% {{inventory}}
环己酮介绍:

Reference Material

This certificate is designed in accordance with ISO 17034 and ISO Guide 31. This reference material (RM) was designed,produced and verified in accordance with ISO/IEC 17025, ISO 17034 and a registered quality management system ISO9001.

Uncertainty

The certified value(s) and uncertainty(ies) are determined in accordance with ISO 17034 with an 95% confidence level (k=2). Uncertainty is based on the Total Combined Uncertainty, including uncertainties of characterisation, homogeneity and stability testing. Stability values are based on real evidence opposed to simulation.

The producer certifies that this reference material meets the specification stated in this certificate until the expiry date, provided it is stored unopened at the recommended temperature herein. Product warranties for this reference material are set out in the terms and conditions of purchase.

Intended Use

This RM is intended for use in a laboratory as a calibration and quality control standard or in method development for analytical techniques.

Safety

Proper precautions should be observed while handling. See Safety Data Sheet.

Traceability

The balances used for gravimetric measurements are calibrated with weights traceable to the national standards (DKD). The calibration of the balances is verified daily internally and annually by an external accredited calibration service. Chromatographic methods are traceable to the International System of Units (SI).

Homogeneity

Random replicate samples of the final packaged RM have been analysed to prove homogeneity compliant with ISO 17034.

Storage

The RM should be stored in the original sealed container at the indicated temperature.

Instructions for use

It is recommended to use 1 mg as the minimum sample size and if less material is used, to increase the certified uncertainty by a factor of two for half sample and four for a quarter of sample. If storage after opening is necessary, the RM should be tightly closed and kept from light and moisture. If the RM was in a sealed ampoule, it should be transferred to a vial with minimum head space.

Tel:029-85836892 Web:www.qjbzwz.com Email:qjbzwz@qjbzwz.com

Address:Jiawei Technology Industry Base, Aerospace East Road, Xi’an , Shaanxi Province


您正在浏览的产品:环己酮

手机版:环己酮

以上信息仅供参考,请以实物批次为准!

本公司销售的所有产品仅供实验科研使用,不用于人体及临床诊断。

《室内空气质量标准》与环己酮检测相关内容解读
标准名称及标准号 GB/T 18883-2002《室内空气质量标准》中关于挥发性有机化合物(TVOC)的检测要求,环己酮作为TVOC组分之一适用该标准。
适用范围 适用于室内空气中环己酮等挥发性有机化合物的检测,包括住宅、办公室、公共场所等密闭环境。
核心检测方法 采用气相色谱-质谱联用法(GC-MS)或气相色谱法(GC-FID),以Tenax TA吸附管采样,热解吸后分析。
检出限与定量限 检出限:0.005 mg/m³(GC-MS);定量限:0.015 mg/m³(GC-MS);其他方法需根据仪器性能验证。
质控样品要求 1. 每批次样品需包含空白对照和加标平行样;
2. 加标回收率应为80%-120%;
3. 标准曲线相关系数R²≥0.995。
关键实验步骤 1. 样品采集:以100 mL/min流量采集10 L空气;
2. 热解吸条件:300℃解吸5分钟,载气为高纯氮气;
3. 色谱条件:DB-5MS色谱柱,程序升温(50℃初始,10℃/min升至250℃)。
特别说明 1. 避免采样管暴露于高温或高湿环境;
2. 环己酮易与臭氧反应,需同步记录环境臭氧浓度;
3. 若浓度超过标准限值(0.05 mg/m³),需重复采样验证。