Reference Material

This certificate is designed in accordance with ISO 17034 and ISO Guide 31. This reference material (RM) was designed,produced and verified in accordance with ISO/IEC 17025, ISO 17034 and a registered quality management system ISO9001.

Method of Characterisation

GC/FID

Batch Information

Water Content: <0.30% (by Karl-Fischer-Titration)

Uncertainty

The certified value(s) and uncertainty(ies) are determined in accordance with ISO 17034 with an 95% confidence level (k=2). Uncertainty is based on the Total Combined Uncertainty, including uncertainties of characterisation, homogeneity and stability testing. Stability values are based on real evidence opposed to simulation.

The producer certifies that this reference material meets the specification stated in this certificate until the expiry date, provided it is stored unopened at the recommended temperature herein. Product warranties for this reference material are set out in the terms and conditions of purchase.

Intended Use

This RM is intended for use in a laboratory as a calibration and quality control standard or in method development for analytical techniques.

Safety

Proper precautions should be observed while handling. See Safety Data Sheet.

Traceability

The balances used for gravimetric measurements are calibrated with weights traceable to the national standards (DKD). The calibration of the balances is verified daily internally and annually by an external accredited calibration service. Chromatographic methods are traceable to the International System of Units (SI).

Homogeneity

Random replicate samples of the final packaged RM have been analysed to prove homogeneity compliant with ISO 17034.

Storage

The RM should be stored in the original sealed container at the indicated temperature.

Instructions for use

It is recommended to use 1 mg as the minimum sample size and if less material is used, to increase the certified uncertainty by a factor of two for half sample and four for a quarter of sample. If storage after opening is necessary, the RM should be tightly closed and kept from light and moisture. If the RM was in a sealed ampoule, it should be transferred to a vial with minimum head space.


您正在浏览的产品:叔丁基苯

手机版:叔丁基苯

本公司销售的所有产品仅供实验科研使用,不用于人体及临床诊断。

标准名称及标准号
GB/T 18883-2002《室内空气质量标准》
适用范围
适用于室内空气中挥发性有机化合物(VOCs)的检测,包括叔丁基苯(CAS:98-06-6)及其他苯系物的限值要求和检测方法。
核心检测方法
采用气相色谱法(GC)或气相色谱-质谱联用(GC-MS)进行定性和定量分析,采样方式为活性炭吸附管富集,二硫化碳溶剂解吸。
检出限与定量限
叔丁基苯的检出限为0.005 mg/m³,定量限为0.015 mg/m³。当采样体积为10 L时,最低检测浓度为0.5 μg/m³。
质控样品要求
每批次样品需包含空白样、平行样及加标样。平行样相对偏差应≤15%,加标回收率需在80%-120%范围内。
关键实验步骤
1. 活性炭管预清洗后采样,流量0.5 L/min,采样时间20-30分钟;
2. 用二硫化碳解吸,超声处理30分钟;
3. 上机分析,采用外标法定量。
特别说明
叔丁基苯在高温下易挥发,实验过程需严格控温。若与其他VOCs共存,需优化色谱分离条件以避免干扰。