Ag, Al, B, Ba, Be, Bi, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, Pb, Sb, Ti, Tl, V, Zn
-
Ag Al B Ba Be Ca Cd Co Cu Fe K Mg Mn Mo Na Ni Pb Sb Ti Tl V Zn
GNM-M2211219-2013 | 100ml
-
Ag Al B Ba Be Ca Cd Co Cr Cu Fe K Mg Mn Mo Na Ni Pb Sb Ti Tl Zn
GNM-M2211109-2013 | 100ml
-
Ag, Al, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, Pb, Sb, Sr, Ti, Tl, V, Zn
GNM-M231685-2013 | 100ml
-
Al, B, Ba, Be, Ca, Cd, Co, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, Pb, Sb, Ti, Tl, V, Zn
GNM-M216437-2013 | 100ml
-
Ag Al As B Ba Be Ca Cd Co Cr Cu Fe K Mg Mn Mo Na Ni Pb Sb Se Ti Tl V Zn
GNM-M2510199-2013 | 100ml
-
Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, Mg, Mn, Mo, Na, Ni, Pb, Sb, Se, Ti, Tl, V, Zn,K
GNM-M253312-2013 | 100ml
-
Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, Pb, Sb, Se, Ti, Tl, V, Zn
GNM-M252187-2013 | 100ml
介质及浓度 : 10%HNO3,1%HF, 有效期(月) : 12;
您正在浏览的产品:24种金属元素混标溶液/银(Ag)铝(Al)硼(B)钡(Ba)铍(Be)铋(Bi)钙(Ca)镉(Cd)钴(Co)铬(Cr)铜(Cu)铁(Fe)钾(K)镁(Mg)锰(Mn)钼(Mo)钠(Na)镍(Ni)铅(Pb)锑(Sb)钛(Ti)铊(Tl)钒(V)锌(Zn)/介质:10%HNO3,1%HF
手机版:24种金属元素混标溶液/银(Ag)铝(Al)硼(B)钡(Ba)铍(Be)铋(Bi)钙(Ca)镉(Cd)钴(Co)铬(Cr)铜(Cu)铁(Fe)钾(K)镁(Mg)锰(Mn)钼(Mo)钠(Na)镍(Ni)铅(Pb)锑(Sb)钛(Ti)铊(Tl)钒(V)锌(Zn)/介质:10%HNO3,1%HF
本公司销售的所有产品仅供实验科研使用,不用于人体及临床诊断。
2. 使用电感耦合等离子体质谱仪(ICP-MS)检测
3. HF/HNO₃混合酸体系消解含硅基质样品
4. 内标法校正基体干扰和仪器漂移
2. 平行样比例≥10%
3. 基体加标回收率控制在80%-120%
4. 使用标准参考物质(SRM)验证准确性
5. 内标回收率监控要求60%-125%
2. 赶酸处理:消解后150℃赶酸至近干,1% HNO₃定容
3. 仪器分析:
• 调谐仪器灵敏度、氧化物、双电荷等指标
• 建立内标溶液在线加入系统(选用Rh, In, Re等)
• 设置质量数扫描参数,避免质谱干扰
4. 校准曲线:至少5个浓度点,相关系数R²≥0.995
2. 干扰校正:
• 采用碰撞反应池技术消除多原子离子干扰
• ²⁰²Hg对²⁰²Tl的干扰需数学校正
3. 介质匹配:标准溶液需与样品保持相同酸介质浓度(10% HNO₃+1% HF)
4. 记忆效应:高浓度样品后需延长冲洗时间(特别是Hg, B, Ba)
2. 电感耦合等离子体发射光谱仪(ICP-OES)检测
3. 优化谱线选择(推荐谱线波长)
4. HF/HNO₃体系消解硅酸盐基体
2. 平行双样测定,偏差≤20%
3. 每批带1个有证标准物质
4. 校准曲线中点浓度核查,偏差≤10%
• 固体废物粉碎过100目筛
• 含水率>10%需105℃烘干
2. 微波消解程序:
• 优化观测高度和载气流量
• 设置背景校正点(峰两侧)
4. 基体匹配:标准曲线酸度与样品保持一致
• 使用耐HF进样系统(铂金中心管、PFA雾化器)
• 实验后需用5%硼酸溶液冲洗管路
2. 谱线干扰:
• Fe对Co 228.616nm的干扰需校正
• Ca对Al 396.152nm的干扰需校正
3. 稳定性要求:连续进样RSD≤5%
以上信息仅供参考,请以相应标准的原文为准!