• 欢迎来到萘析商城
苏丹红Ⅲ_85-86-9,苏丹红Ⅲ
图片仅供参考,具体产品以实物为准!

苏丹红Ⅲ

BW903062 {{goodObj.price > 0 ? '¥' + goodObj.price : '咨询'}} ¥{{goodObj.sell_price || 0}} 咨询 85-86-9 100mg {{goodObj.date}} 秦境 {{item.norm}} 94.8% {{inventory}}
苏丹红Ⅲ介绍:

REFERENCE MATERIAL CERTIFICATE

Reference Material

This certificate is designed in accordance with ISO 17034 and ISO Guide 31. This reference material (RM) was designed,produced and verified in accordance with ISO/IEC 17025, ISO 17034 and a registered quality management system ISO9001.

Product Name

Sudan 3

Product Code

BW903062

Lot Number

23081553

CAS No.

85-86-9

Mol. Formula

C22H16N4O

Mol. Weight

352.39

Certified on

18 Aug 2023

Expiry Date

18 Aug 2028

Storage Temp

20°C ± 4°C

Specification

100mg

CERTIFIED

Purity

CERTIFIED

Expanded Uncertainty (U)

Approved by

94.8%

1.0%

Uncertainty

The certified value(s) and uncertainty(ies) are determined in accordance with ISO 17034 with an 95% confidence level (k=2). Uncertainty is based on the Total Combined Uncertainty, including uncertainties of characterisation, homogeneity and stability testing. Stability values are based on real evidence opposed to simulation.

The producer certifies that this reference material meets the specification stated in this certificate until the expiry date, provided it is stored unopened at the recommended temperature herein. Product warranties for this reference material are set out in the terms and conditions of purchase.

Intended Use

This RM is intended for use in a laboratory as a calibration and quality control standard or in method development for analytical techniques.

Safety

Proper precautions should be observed while handling. See Safety Data Sheet.

Traceability

The balances used for gravimetric measurements are calibrated with weights traceable to the national standards (DKD). The calibration of the balances is verified daily internally and annually by an external accredited calibration service. Chromatographic methods are traceable to the International System of Units (SI).

Homogeneity

Random replicate samples of the final packaged RM have been analysed to prove homogeneity compliant with ISO 17034.

Storage

The RM should be stored in the original sealed container at the indicated temperature.

Instructions for use

It is recommended to use 1 mg as the minimum sample size and if less material is used, to increase the certified uncertainty by a factor of two for half sample and four for a quarter of sample. If storage after opening is necessary, the RM should be tightly closed and kept from light and moisture. If the RM was in a sealed ampoule, it should be transferred to a vial with minimum head space.


您正在浏览的产品:苏丹红Ⅲ

手机版:苏丹红Ⅲ

本公司销售的所有产品仅供实验科研使用,不用于人体及临床诊断。

标准名称及标准号
GB/T 19681-2005 食品中苏丹红染料的检测方法 高效液相色谱法
适用范围
本标准适用于食品中苏丹红Ⅲ(CAS:85-86-9)的定性鉴别和定量检测,涵盖辣椒酱、调味品、油脂等基质。
核心检测方法
使用高效液相色谱法(HPLC)结合二极管阵列检测器(DAD),色谱柱为C18反相柱,流动相为乙腈-水梯度洗脱系统,检测波长478 nm。
检出限与定量限
苏丹红Ⅲ的检出限(LOD)为0.01 mg/kg,定量限(LOQ)为0.03 mg/kg,需通过加标回收实验验证基质干扰。
质控样品要求
每批次检测需包含空白样品、加标回收样品(加标浓度接近LOQ和实际样品浓度),平行样数量≥10%总样品量,回收率控制在70%-120%。
关键实验步骤
1. 样品前处理:均质后经正己烷脱脂,乙腈萃取
2. 净化:固相萃取柱(如中性氧化铝)去除杂质
3. 浓缩:氮吹浓缩至干后用流动相复溶
4. 色谱条件:流速1.0 mL/min,柱温30℃,进样量10 μL
特别说明
1. 苏丹红Ⅲ标准品需避光保存于-20℃
2. 检测过程需严格避免脂溶性色素干扰
3. 阳性样品需通过液相色谱-质谱联用(LC-MS)确认
4. 实验室温度应控制在25±2℃以确保色谱稳定性