13种SVOC混标/GB/T10004-2008|GB/T 10004-2008 VOC Mixture 574 GB/T 10004-2008 VOC Mixture 574
-
27种VOC混标/GB 5749-2006|VOC Mixture for GB 5749-2006 VOC Mixture for GB 5749-2006
DRE-GA09000570ME | 1ml
-
7种卤代烃混标/GB 18581-2009/HJ/T 201-2005|GB 18581-2009 Chlorinated VOC Mixture 552 GB 18581-2009 Chlorinated VOC Mixture 552
DRE-A50000552ME | 1ml
-
24种VOC混标/GB 3838-2002|GB 3838-2002 VOC Mixture GB 3838-2002 VOC Mixture
DRE-A50000626ME | 1ml
-
5种VOC混标/GB/T 5750.8-2006 附录A|GB/T 5750.8-2006 App. A VOC Mixture 632 GB/T 5750.8-2006 App. A VOC Mixture 632
DRE-A50000632ME | 1ml
-
31种VOC混标/GB 24410-2009|GB 24410-2009 VOC Mixture 640 GB 24410-2009 VOC Mixture 640
DRE-A50000640ME | 1ml
-
22种VOC混标/GB 18582-2008|VOC Mixture 603 VOC Mixture 603
DRE-A50000603AL | 1ml
-
19种VOC混标/HJ/T 400-2007/GB/T 27630-2011|VOC Mixture for GB/T 27630-2011 VOC Mixture for GB/T 27630-2011
DRE-GA09000559ME | 1ml
产品类型:标准物质(RM)-溶液型
产品品牌:Dr.E
您正在浏览的产品:13种SVOC混标/GB/T10004-2008|GB/T 10004-2008 VOC Mixture 574
手机版:13种SVOC混标/GB/T10004-2008|GB/T 10004-2008 VOC Mixture 574
本公司销售的所有产品仅供实验科研使用,不用于人体及临床诊断。
GB/T 10004-2008《包装用塑料复合膜、袋 干法复合、挤出复合》
适用于食品、药品等包装用塑料复合膜和复合袋的质量控制,特别规定了对挥发性有机化合物(VOC)及半挥发性有机化合物(SVOC)残留限量的检测要求。
采用气相色谱法(GC)检测溶剂残留:
1. 样品在密闭容器中加热释放残留溶剂
2. 顶空进样或溶剂提取进样
3. 使用毛细管色谱柱分离目标化合物
4. FID检测器进行定性和定量分析
1. 苯系物检出限 ≤ 0.01 mg/m²
2. 总溶剂残留定量限 ≤ 5.0 mg/m²
3. 标准要求溶剂残留总量 ≤ 5.0 mg/m²
4. 苯类溶剂单独限量 ≤ 0.5 mg/m²
1. 每批次检测需包含空白对照和加标样品
2. 使用有证标准物质(如13种SVOC混标)进行校准
3. 平行样数量 ≥ 2个/批次
4. 加标回收率应控制在85%-115%范围内
5. 标准曲线相关系数R² ≥ 0.995
1. 样品制备:将复合膜裁成0.2dm²碎片置于顶空瓶
2. 释放条件:100℃±1℃恒温60min
3. 色谱条件:
- 色谱柱:极性毛细管柱(如DB-WAX)
- 程序升温:40℃(5min)→10℃/min→200℃(5min)
- 进样口温度:200℃,检测器温度:250℃
4. 定量分析:外标法峰面积定量
1. 检测环境要求:恒温恒湿实验室(23℃±2℃,50%±5%RH)
2. 重点监控物质包括:苯、甲苯、二甲苯、乙苯等苯系物
3. 对于厚度>0.05mm的复合袋需特殊处理取样
4. 检测报告需明确标注使用标准物质的批号及浓度
5. 当检出疑似阳性结果时需使用质谱(GC-MS)确证
以上信息仅供参考,请以相应标准的原文为准!