9种PCB混标/GB/T 14848-2017|GB/T 14848-2017 PCB Mixture 132 GB/T 14848-2017 PCB Mixture 132
-
11种SVOC混标/GB/T 14848-2017|GB/T 14848-2017 SVOC Mixture 138 GB/T 14848-2017 SVOC Mixture 138
DRE-A50000138DI | 1ml
-
8种有机氯农药混标/GB/T 5750.9-2006/GB/T 14848-2017|GB/T 5750.9-2006, GB/T 14848-2017 Organochlorine Pesticides Mixture 122 GB/T 5750.9-2006, GB/T 14848-2017 Organochlorine Pesticides Mixture 122
DRE-A50000122TO | 1mL
-
9种PCB混标,适用GB/T 14848-2017 PCB Mix 9
MWLT600760-HE | 1mL
-
11种农药混标/GB/T 14848-2017
DRE-A50000522TO | 1ml
-
18种PCB混标/HJ 715-2014/HJ 743-2015/HJ 891-2017/HJ 922-2017|PCB Mixture for HJ 743-2015 PCB Mixture for HJ 743-2015
DRE-GA09000583HE | 1ml
-
SN/T 2463-2010 PCB混标|SN/T 2463-2010 PCB Mixture 670 SN/T 2463-2010 PCB Mixture 670
DRE-A50000670HE | 1ml
-
18种PCB混标/HJ 715-2014/HJ 743-2015/HJ 891-2017/HJ 922-2017|PCB Mixture for HJ 715-2014 / HJ 743-2015 PCB Mixture for HJ 715-2014 / HJ 743-2015
DRE-GA09000584TO | 1ml
产品类型:标准物质(RM)-溶液型
产品品牌:Dr.E
您正在浏览的产品:9种PCB混标/GB/T 14848-2017|GB/T 14848-2017 PCB Mixture 132
手机版:9种PCB混标/GB/T 14848-2017|GB/T 14848-2017 PCB Mixture 132
本公司销售的所有产品仅供实验科研使用,不用于人体及临床诊断。
2. 样品需经液液萃取或固相萃取预处理
3. 内标法定量,使用同位素标记化合物作为内标物
4. 方法依据HJ 699-2014《水质 多氯联苯的测定 气相色谱-质谱法》
2. 定量限:0.0003 mg/L
3. 单个PCB同类物定量限:0.00003-0.0001 mg/L
4. 标准限值:PCB总量≤0.0005 mg/L(Ⅲ类水标准)
2. 加标回收率范围:70%-130%
3. 相对标准偏差(RSD)≤25%
4. 必须使用有证标准物质(如PCB混标)校准
5. 每12小时需进行中间浓度点核查
2. 萃取:1L水样加入替代物标准,用正己烷液液萃取
3. 浓缩:氮吹浓缩至0.5mL,溶剂置换为正己烷
4. 净化:通过硅胶柱或弗罗里硅土柱净化
5. 上机分析:GC-MS检测,DB-5MS色谱柱(30m×0.25mm×0.25μm)
6. 定性定量:选择离子监测模式,内标法定量
2. 实验室温度控制:萃取和浓缩过程≤25℃,避免PCBs挥发损失
3. 玻璃器皿处理:使用前需400℃烘烤4小时去除有机污染物
4. 方法验证:新批次标准物质需进行方法检出限验证
5. 结果报告:当PCB总量<0.0001mg/L时报告"未检出",同时注明方法检出限