二氯甲烷中7种硝基苯混标/HJ 738-2015/HJ 739-2015
-
正己烷中7种硝基苯混标/HJ 738-2015/HJ 739-2015
BW04004 | 1.2mL
-
正己烷中7种硝基苯混标/HJ 738-2015/HJ 739-2015
BW08011 | 1.2mL
-
7种硝基苯类混标/HJ 738-2015/HJ 739-2015|Nitrobenzene Mixture for HJ 738-2015 Nitrobenzene Mixture for HJ 738-2015
DRE-GA09000538HE | 1ml
-
2种替代物混标/HJ 713-2014/HJ 714-2014/HJ 735-2015/HJ 736-2015 (1,2-二氯苯-D4、二氯甲烷-D2)|HJ 713, HJ 714-2014, HJ 735, HJ 736-2015 VOC Internal StandardsMixture 118 HJ 713, HJ 714-2014, HJ 735, HJ 736-2015 VOC Internal StandardsMixture 118
DRE-A50000118ME | 1ml
-
7种硝基苯类混标/HJ 738-2015/HJ 739-2015 Nitrobenzene Mixture for HJ 738-2015 2000 µg/mL in Hexane
ZDR-GA09000538HE | 1ml
-
3种内标物混标/HJ 713-2014/HJ 714-2014/HJ 735-2015/HJ 736-2015 (氟苯、1-氯-2-溴丙烷、4-溴氟苯)|HJ 713, HJ 714-2014, HJ 735, HJ 736-2015 VOC Mixture 116 HJ 713, HJ 714-2014, HJ 735, HJ 736-2015 VOC Mixture 116
DRE-A50000116ME | 1ml
-
正己烷中7种硝基苯类混标/HJ 738/HJ 739 7 Nitrobenzoates Mix/HJ 738/HJ 739
MCEM590972-HE | 1mL
产品分类:有机类
您正在浏览的产品:二氯甲烷中7种硝基苯混标/HJ 738-2015/HJ 739-2015
手机版:二氯甲烷中7种硝基苯混标/HJ 738-2015/HJ 739-2015
本公司销售的所有产品仅供实验科研使用,不用于人体及临床诊断。
2. 样品前处理:二氯甲烷溶剂解吸
3. 仪器分析:气相色谱仪(GC)配备电子捕获检测器(ECD)
4. 定性定量:保留时间定性,外标法定量
其他硝基苯类化合物检出限:0.001μg/m³
定量限通常为检出限的3倍
2. 每20个样品至少分析1个平行样
3. 每批样品需做加标回收实验,回收率应在70%-130%
4. 使用有证标准物质进行校准
2. 解吸:用5mL二氯甲烷分两次解吸吸附管
3. 浓缩:氮吹浓缩至1.0mL
4. GC分析条件:
- 色谱柱:DB-1701(30m×0.32mm×0.25μm)
- 柱温:80℃(2min)→10℃/min→220℃(5min)
- 进样口温度:220℃
- 检测器温度:300℃
2. 样品需避光保存,解吸后24h内完成分析
3. 注意硝基苯类化合物在高温下易分解,严格控制分析温度
2. 样品前处理:二氯甲烷溶剂解吸
3. 仪器分析:气相色谱-质谱联用仪(GC-MS)
4. 定性定量:保留时间和特征离子定性,内标法定量
其他硝基苯类化合物检出限:0.0005μg/m³
定量限通常为检出限的3倍
2. 使用同位素内标(如硝基苯-d5)监控回收率
3. 每批样品需做加标回收实验
4. 定期进行仪器校准和质量校正
2. 解吸:用含内标物的二氯甲烷解吸
3. GC-MS分析条件:
- 色谱柱:DB-5MS(30m×0.25mm×0.25μm)
- 柱温:50℃(1min)→15℃/min→280℃(5min)
- 离子源:EI源
- 扫描模式:选择离子监测(SIM)
2. 使用内标法定量可有效降低前处理损失带来的误差
3. 注意质谱检测器的污染问题,定期维护离子源
以上信息仅供参考,请以相应标准的原文为准!