苏丹红Ⅰ介绍:

Reference Material

This certificate is designed in accordance with ISO 17034 and ISO Guide 31. This reference material (RM) was designed,produced and verified in accordance with ISO/IEC 17025, ISO 17034 and a registered quality management system ISO9001.

Uncertainty

The certified value(s) and uncertainty(ies) are determined in accordance with ISO 17034 with an 95% confidence level (k=2). Uncertainty is based on the Total Combined Uncertainty, including uncertainties of characterisation, homogeneity and stability testing. Stability values are based on real evidence opposed to simulation.

The producer certifies that this reference material meets the specification stated in this certificate until the expiry date, provided it is stored unopened at the recommended temperature herein. Product warranties for this reference material are set out in the terms and conditions of purchase.

Intended Use

This RM is intended for use in a laboratory as a calibration and quality control standard or in method development for analytical techniques.

Safety

Proper precautions should be observed while handling. See Safety Data Sheet.

Traceability

The balances used for gravimetric measurements are calibrated with weights traceable to the national standards (DKD). The calibration of the balances is verified daily internally and annually by an external7 accredited calibration service. Chromatographic methods are traceable to the International System of Units (SI).

Homogeneity

Random replicate samples of the final packaged RM have been analysed to prove homogeneity compliant with ISO 17034.

Storage

The RM should be stored in the original sealed container at the indicated temperature.

Instructions for use

It is recommended to use 1 mg as the minimum sample size and if less material is used, to increase the certified uncertainty by a factor of two for half sample and four for a quarter of sample. If storage after opening is necessary, the RM should be tightly closed and kept from light and moisture. If the RM was in a sealed ampoule, it should be transferred to a vial with minimum head space.


您正在浏览的产品:苏丹红Ⅰ

手机版:苏丹红Ⅰ

本公司销售的所有产品仅供实验科研使用,不用于人体及临床诊断。

标准名称及标准号
GB/T 19681-2005 《食品中苏丹红染料的检测方法 高效液相色谱法》
适用范围
适用于辣椒酱、调味品、含油食品等样品中苏丹红Ⅰ(CAS:842-07-9)的定性及定量检测。
核心检测方法
高效液相色谱法(HPLC),使用C18色谱柱,流动相为乙腈-水梯度洗脱,检测波长478 nm。苏丹红Ⅰ通过保留时间和紫外光谱比对定性,外标法定量。
检出限与定量限
方法检出限(LOD)为0.01 mg/kg,定量限(LOQ)为0.03 mg/kg。
质控样品要求
1. 空白样品加标回收率需在70%-120%范围内;
2. 每批次样品需至少插入1个阳性加标质控样和1个空白对照;
3. 标准曲线相关系数≥0.995。
关键实验步骤
1. 样品处理:样品经乙腈提取,中性氧化铝柱净化;
2. 浓缩定容:氮吹浓缩后用乙腈定容;
3. 色谱分析:按梯度条件运行HPLC,记录峰面积;
4. 数据分析:通过标准曲线计算含量。
特别说明
1. 苏丹红Ⅰ需避光保存,标准溶液现配现用;
2. 实验过程中需避免油脂类交叉污染;
3. 阳性样品建议通过质谱法(如LC-MS)进一步确认。