• 欢迎来到萘析商城
当前位置: 首页 标准物质 有机类 单标 3-硝基苯胺
3-硝基苯胺_99-09-2,3-硝基苯胺
图片仅供参考,具体产品以实物为准!

3-硝基苯胺

BW903029 {{goodObj.price > 0 ? '¥' + goodObj.price : '咨询'}} ¥{{goodObj.sell_price || 0}} 咨询 99-09-2 100mg {{goodObj.date}} 秦境 {{item.norm}} 99.9% {{inventory}}
3-硝基苯胺介绍:

Reference Material

This certificate is designed in accordance with ISO17034 and ISO Guide 31. This reference material (RM) was designed,produced andverified in accordance with ISO/IEC 17025, ISO 17034 and a registered qualitymanagement system ISO9001.

Product Name

3-Nitroaniline

Product Code

BW903029

Lot Number

23061580

CAS No.

99-09-2

Mol. Formula

C6H6N2O2

Mol. Weight

138.12

Certified on

26 Jun 2023

Expiry Date

29 Jun 2028

Storage Temp

4°C ± 4°C

Specification

100mg

CERTIFIED

Purity

CERTIFIED

Expanded Uncertainty (U)

Approved by

99.9%

1.0%

Methodof Characterisation

GC/FID

Batch Information

Water Content: <0.30% (by Karl-Fischer-Titration)

Uncertainty

The certified value(s) and uncertainty(ies) aredetermined in accordance with ISO 17034 with an 95% confidence level (k=2).Uncertainty is based on the Total Combined Uncertainty, including uncertaintiesof characterisation, homogeneity and stability testing. Stability values arebased on real evidence opposed to simulation.

The producer certifies that this reference materialmeets the specification stated in this certificate until the expiry date,provided it is stored unopened at the recommended temperature herein. Productwarranties for this reference material are set out in the terms and conditionsof purchase.

Intended Use

This RM is intended for use in a laboratory as acalibration and quality control standard or in method development for analyticaltechniques.

Safety

Proper precautions should be observed whilehandling. See Safety Data Sheet.

Traceability

The balances used for gravimetric measurements arecalibrated with weights traceable to the national standards (DKD). Thecalibration of the balances is verified daily internally and annually by anexternal accredited calibration service. Chromatographic methods are traceableto the International System of Units (SI).

Homogeneity

Random replicate samples of the final packaged RMhave been analysed to prove homogeneity compliant with ISO 17034.

Storage

The RM should be stored in the original sealedcontainer at the indicated temperature.

Instructions for use

It is recommended to use 1 mg as the minimum samplesize and if less material is used, to increase the certified uncertainty by afactor of two for half sample and four for a quarter of sample. If storageafter opening is necessary, the RM should be tightly closed and kept from lightand moisture. If the RM was in a sealed ampoule, it should be transferred to avial with minimum head space.

The producer certifies that this reference materialmeets the specification stated in this certificate until the expiry date,provided it is stored unopened at the recommended temperature herein. Productwarranties for this reference material are set out in the terms and conditionsof purchase.

Intended Use

This RM is intended for use in a laboratory as acalibration and quality control standard or in method development foranalytical techniques.

Safety

Proper precautions should be observed whilehandling. See Safety Data Sheet.

Traceability

The balances used for gravimetric measurements arecalibrated with weights traceable to the national standards (DKD). Thecalibration of the balances is verified daily internally and annually by anexternal7 accredited calibration service. Chromatographic methods are traceableto the International System of Units (SI).

Homogeneity

Random replicate samples of the final packaged RMhave been analysed to prove homogeneity compliant with ISO 17034.

Storage

The RM should be stored in the original sealedcontainer at the indicated temperature.

Instructions for use

It is recommended to use 1 mg as the minimum samplesize and if less material is used, to increase the certified uncertainty by afactor of two for half sample and four for a quarter of sample. If storageafter opening is necessary, the RM should be tightly closed and kept from lightand moisture. If the RM was in a sealed ampoule, it should be transferred to avial with minimum head space.


您正在浏览的产品:3-硝基苯胺

手机版:3-硝基苯胺

本公司销售的所有产品仅供实验科研使用,不用于人体及临床诊断。

标准名称及标准号
HJ 676-2013 水质 硝基苯胺类化合物的测定 气相色谱法
适用范围
适用于地表水、地下水、工业废水和生活污水中3-硝基苯胺等硝基苯胺类化合物的测定,目标物浓度范围为0.005 mg/L~0.5 mg/L。
核心检测方法
使用气相色谱-电子捕获检测器(GC-ECD)进行分离检测,采用液液萃取(LLE)或固相萃取(SPE)对水样进行前处理,通过保留时间定性,外标法定量。
检出限与定量限
方法检出限(MDL)为0.001 mg/L,定量下限(LOQ)为0.005 mg/L。需根据实际水样基体进行验证。
质控样品要求
每批次样品需包含空白加标和平行样,加标回收率应控制在70%~130%,相对偏差≤20%。空白样品中目标物浓度需低于检出限。
关键实验步骤
1. 样品萃取:调节水样pH至中性,用二氯甲烷进行液液萃取,浓缩至1 mL;
2. 仪器分析:进样量1 μL,柱温程序升温(初始50℃保持2 min,以10℃/min升至250℃);
3. 数据处理:绘制校准曲线(≥5个浓度点),相关系数≥0.995。
特别说明
● 含高浓度有机物或悬浮物的样品需经玻璃纤维滤膜过滤;
● 实验过程需避光操作,防止目标物光解;
● 需定期验证色谱柱分离度(相邻峰分离度≥1.5)。