Bisphenol F quality control substance in acrylonitrile-butadiene-styrene (ABS)
-
Bisphenol F quality control substance in acrylonitrile-butadiene-styrene (ABS)
RMJ018 | 20g/瓶
-
Bisphenol S quality control substance in acrylonitrile-butadiene-styrene (ABS)
RMJ010 | 20g/瓶
-
Bisphenol S quality control substance in acrylonitrile-butadiene-styrene (ABS)
RMJ011 | 20g/瓶
-
Bisphenol S quality control substance in acrylonitrile-butadiene-styrene (ABS)
RMJ009 | 20g/瓶
-
Quality control substance of Decron in Acrylonitrile Butadiene Styrene (ABS)
RMD006 | 20g/瓶
-
TSCA five quality control substances in acrylonitrile butadiene styrene (ABS)
RMH010 | 20g/瓶
-
TSCA five quality control substances in acrylonitrile butadiene styrene (ABS)
RMH009 | 20g/瓶
您正在浏览的产品:丙烯腈-丁二烯-苯乙烯(ABS)中双酚F质量控制物质(US EPA 3550C:2007 )
手机版:丙烯腈-丁二烯-苯乙烯(ABS)中双酚F质量控制物质(US EPA 3550C:2007 )
本公司销售的所有产品仅供实验科研使用,不用于人体及临床诊断。
标准名称及标准号: GB/T 32115-2015《口腔护理产品中禁限用物质双酚基丙烷(BPA)的测定 高效液相色谱法》
本标准规定了口腔护理产品中双酚基丙烷(双酚A)的高效液相色谱检测方法,其原理及适用范围可扩展至丙烯腈-丁二烯-苯乙烯(ABS)材料中双酚F的检测。
适用于塑料制品(含ABS材料)、橡胶制品及口腔护理产品中双酚类化合物(含双酚F)的定量分析。明确涵盖聚合物材料中有机污染物的溶剂提取-色谱检测流程。
1. 提取方法: 超声辅助溶剂萃取(参考US EPA 3550C索氏提取原理),使用乙腈或甲醇作为提取溶剂
2. 分离检测: 高效液相色谱法(HPLC)配合紫外检测器(UV)或荧光检测器(FLD)
3. 色谱条件: C18反相色谱柱(250mm×4.6mm,5μm),流动相为乙腈-水梯度洗脱
检出限(LOD): 0.05 mg/kg(紫外检测器)
定量限(LOQ): 0.20 mg/kg(紫外检测器)
注:荧光检测器灵敏度可提高3-5倍,实际限值需通过空白基质加标实验验证
1. 空白对照: 每批次需包含未接触样品的溶剂空白
2. 加标回收: 每10个样品设置1个基质加标样,加标浓度0.5-2.0 mg/kg
3. 平行样: 样品检测平行双样,相对偏差≤15%
4. 标准曲线: 线性范围0.1-10 mg/L,相关系数R²≥0.999
步骤1:样品前处理
将ABS材料粉碎至粒径≤1mm,准确称取1.00g样品,加入20mL乙腈,40℃超声萃取30min
步骤2:净化浓缩
萃取液经0.22μm有机滤膜过滤,氮吹浓缩至1mL
步骤3:色谱分析
色谱条件:流速1.0mL/min,柱温30℃,检测波长227nm(紫外),进样量10μL
步骤4:定性定量
以双酚F标准品保留时间定性,外标法定量
1. ABS材料需充分粉碎以保证提取效率,避免局部过热导致双酚F降解
2. 若检测荧光响应,激发波长228nm/发射波长310nm可提升灵敏度
3. 实验过程需使用玻璃器皿,禁用含双酚基质的塑料制品
4. 当结果接近定量限时,建议采用质谱确证(如LC-MS/MS)
以上信息仅供参考,请以相应标准的原文为准!