Bisphenol F quality control substance in acrylonitrile-butadiene-styrene (ABS)
-
Bisphenol F quality control substance in acrylonitrile-butadiene-styrene (ABS)
RMJ019 | 20g/瓶
-
Bisphenol S quality control substance in acrylonitrile-butadiene-styrene (ABS)
RMJ010 | 20g/瓶
-
Bisphenol S quality control substance in acrylonitrile-butadiene-styrene (ABS)
RMJ011 | 20g/瓶
-
Bisphenol S quality control substance in acrylonitrile-butadiene-styrene (ABS)
RMJ009 | 20g/瓶
-
TSCA five quality control substances in acrylonitrile butadiene styrene (ABS)
RMH009 | 20g/瓶
-
TSCA five quality control substances in acrylonitrile butadiene styrene (ABS)
RMH010 | 20g/瓶
-
Hexabromocyclododecane quality control substance in acrylonitrile-butadiene-styrene
RMD003 | 20g/瓶
您正在浏览的产品:丙烯腈-丁二烯-苯乙烯(ABS)中双酚F质量控制物质(US EPA 3550C:2007 )
手机版:丙烯腈-丁二烯-苯乙烯(ABS)中双酚F质量控制物质(US EPA 3550C:2007 )
本公司销售的所有产品仅供实验科研使用,不用于人体及临床诊断。
GB/T 34436-2017《玩具材料中双酚A的测定 高效液相色谱-串联质谱法》
适用于丙烯腈-丁二烯-苯乙烯(ABS)等玩具材料中双酚类物质的定量检测。该标准涵盖塑料、涂层、胶粘剂等多种基质,检测对象包括双酚A及其结构类似物(如双酚F)。
1. 样品前处理:采用溶剂萃取法(乙腈/甲醇体系)结合超声波辅助提取
2. 净化方式:固相萃取柱(SPE)净化
3. 检测设备:高效液相色谱-三重四极杆串联质谱仪(HPLC-MS/MS)
4. 分离模式:C18反相色谱柱梯度洗脱
5. 检测模式:多反应监测(MRM)模式
1. 双酚F方法检出限(MDL):0.05 mg/kg
2. 定量限(LOQ):0.15 mg/kg
3. 线性范围:0.01~1.0 mg/L(相当于0.05~5.0 mg/kg)
4. 相对标准偏差(RSD):≤8.0%(浓度>LOQ时)
1. 每批次需包含试剂空白、基质空白和加标回收样
2. 加标浓度:LOQ、2×LOQ和10×LOQ三个水平
3. 回收率范围:80%~110%
4. 每20个样品插入1个质控样
5. 使用有证标准物质进行校准曲线验证
1. 样品制备:将ABS样品破碎至粒径<1mm
2. 精确称取0.5g样品,加入10mL乙腈溶液
3. 超声萃取:40℃下超声30min(功率300W)
4. 离心净化:8000r/min离心5min取上清液
5. SPE净化:HLB柱活化后上样,甲醇洗脱
6. 氮吹浓缩:40℃下浓缩至近干,流动相定容
7. LC-MS/MS分析:进样量10μL,柱温40℃
1. 双酚F检测需优化质谱参数:定性离子对m/z 201.1>93.1/119.1,碰撞能量分别设为20eV和15eV
2. ABS基质干扰需采用基质匹配标准曲线校正
3. 样品制备过程需避免使用含双酚类物质的塑料器皿
4. 当检测值接近限量时,需通过离子丰度比(Q/q)确认(允许偏差≤20%)
5. 方法验证表明:双酚F在ABS中的平均回收率为92.3%±5.7%
以上信息仅供参考,请以相应标准的原文为准!