氯化甲基汞和氯化乙基汞混标/HJ 977-2018 HJ 997-2018 Mercury Compounds Mixture 125 1000 µg/mL in Toluene
-
氯化甲基汞和氯化乙基汞混标/HJ 977-2018|HJ 977-2018 Mercury Compounds Mixture 125 HJ 977-2018 Mercury Compounds Mixture 125
DRE-A50000125TO | 1ml
-
甲醇中氯化甲基汞/氯化乙基汞混标(以甲基汞/乙基汞计)/GB/T14204-1993/HJ 977-2018 Mercury Compounds Mixture
BW1103-1 | 1mL
-
氯化甲基汞/氯化乙基汞混标/GB/T 14204-1993/HJ 977-2018 Organic Mercury Mix 2
MCEM591021-ME | 1.2mL
-
氯化甲基汞/氯化乙基汞混标/GB/T 14204-1993/HJ 977-2018/溶剂:甲醇 Organic Mercury Mix 2
MCEM591021-ME | 1.2mL
-
18种PCB混标/HJ 715-2014/HJ 743-2015/HJ 891-2017/HJ 922-2017 PCB Mixture for HJ 715-2014 / HJ 743-2015 100 µg/mL in Toluene
ZDR-GA09000584TO | 1ml
-
64种SVOCs混标/HJ 834-2017/HJ 951-2018 HJ 834-2017, HJ 951-2018 VOC & SVOCs Mixture 155 1000 µg/mL in Dichloromethane
ZDR-A50000155DI | 1mL
-
5种内标物混标/HJ 646-2013/HJ 805-2016/HJ 950-2018 HJ 646-2013,HJ 805-2016,HJ 950-2018 Internal Standards Mixture 515 2000 µg/mL in Acetone:n-Hexane
ZDR-A50000515DI | 1ml
中文名称:氯化甲基汞和氯化乙基汞混标/HJ 977-2018
英文名称:HJ 997-2018 Mercury Compounds Mixture 125 1000 µg/mL in Toluene
您正在浏览的产品:氯化甲基汞和氯化乙基汞混标/HJ 977-2018
手机版:氯化甲基汞和氯化乙基汞混标/HJ 977-2018
本公司销售的所有产品仅供实验科研使用,不用于人体及临床诊断。
HJ 977-2018《水质 烷基汞的测定 吹扫捕集/气相色谱-冷原子荧光法》
适用于地表水、地下水、工业废水和生活污水中甲基汞、乙基汞的测定。检测浓度范围为甲基汞0.02~20 ng/L,乙基汞0.04~20 ng/L。
1. 样品经醋酸缓冲溶液酸化后,用四丙基硼化钠衍生化
2. 吹扫捕集系统富集衍生化产物
3. 气相色谱分离
4. 冷原子荧光检测器(GC-CVAFS)定量分析
甲基汞:检出限0.02 ng/L,定量限0.08 ng/L
乙基汞:检出限0.04 ng/L,定量限0.16 ng/L
(当取样量为40 mL时)
1. 空白实验:每批样品(≤20个)至少2个全程序空白
2. 平行样:每批样品≥10%的平行双样,相对偏差≤30%
3. 加标回收:每批样品≥10%的加标回收,回收率70%~130%
4. 校准曲线:相关系数≥0.995,每24小时需重新校准
1. 衍生化:取40 mL水样,加入1 mL醋酸钠缓冲液(pH=4),0.5 mL 1%四丙基硼化钠溶液,室温反应30 min
2. 吹扫捕集:氦气吹扫流量40 mL/min,捕集温度50℃,解吸温度190℃
3. 色谱条件:DB-5MS色谱柱(30 m×0.32 mm×0.25 μm),程序升温从50℃(2 min)以10℃/min升至150℃
4. 检测器:冷原子荧光检测器,激发波长253.7 nm
1. 全程使用聚四氟乙烯容器,避免玻璃器皿吸附
2. 实验室需配备汞专用通风柜,所有废液按危险废物处理
3. 当样品存在余氯时需加入0.1%抗坏血酸消除干扰
4. 每12个样品后需插入质控样验证系统稳定性
以上信息仅供参考,请以相应标准的原文为准!