7种苯氧羧酸类农药混标/HJ 1022-2019 HJ 1022-2019 Pesticides Mixture 14 500 µg/mL in Acetone
-
7种苯氧羧酸类农药混标/HJ 1022-2019|HJ 1022-2019 Pesticides Mixture 14 HJ 1022-2019 Pesticides Mixture 14
DRE-A30000014AC | 1ml
-
7种苯氧羧酸类农药混标/HJ 1022-2019|HJ 1022-2019 Phenoxycarboxylic Pesticides Mixture HJ 1022-2019 Phenoxycarboxylic Pesticides Mixture
DRE-A30000010AC | 1ml
-
7种苯氧羧酸类农药混标/HJ 1022-2019 HJ 1022-2019 Phenoxycarboxylic Pesticides Mixture 10 100 µg/mL in Acetone
ZDR-A30000010AC | 1ml
-
11种三嗪类农药混标/HJ 1052-2019|HJ 1052-2019 Pesticides Mixture 484 HJ 1052-2019 Pesticides Mixture 484
DRE-A50000484AL | 1ml
-
11种三嗪类农药混标/HJ 1052-2019 HJ 1052-2019 Pesticides Mixture 484 100 µg/mL in Acetonitrile
ZDR-A50000484AL | 1ml
-
15种氨基甲酸酯类混标 HJ 961-2018/HJ 1026-2019|HJ 961-2018, HJ 1026-2019 Pesticides Mixture 497 HJ 961-2018, HJ 1026-2019 Pesticides Mixture 497
DRE-A50000497ME | 1ml
-
15种氨基甲酸酯类混标 HJ 961-2018/HJ 1026-2019 HJ 961-2018, HJ 1026-2019 Pesticides Mixture 497 100 µg/mL in Methanol
ZDR-A50000497ME | 1ml
中文名称:7种苯氧羧酸类农药混标/HJ 1022-2019
英文名称:HJ 1022-2019 Pesticides Mixture 14 500 µg/mL in Acetone
您正在浏览的产品:7种苯氧羧酸类农药混标/HJ 1022-2019
手机版:7种苯氧羧酸类农药混标/HJ 1022-2019
本公司销售的所有产品仅供实验科研使用,不用于人体及临床诊断。
HJ 1022-2019《水质 苯氧羧酸类农药的测定 高效液相色谱-串联质谱法》
本标准适用于地表水、地下水、生活污水和工业废水中7种苯氧羧酸类农药的测定。包括2,4-滴、2,4,5-涕、2甲4氯、2,4-滴丙酸、2,4,5-涕丙酸、2,4-滴丁酸和2,4,5-涕丁酸等化合物。
1. 样品前处理:水样经0.22μm滤膜过滤后直接进样
2. 分离方式:C18反相色谱柱梯度洗脱
3. 检测技术:电喷雾电离源(ESI)负离子模式,多反应监测(MRM)
4. 定量方法:同位素内标法或外标法定量
方法检出限范围:0.005~0.01μg/L
定量下限范围:0.02~0.04μg/L
(具体数值需根据仪器性能和实际验证确定,各化合物定量限详见标准附录)
1. 每批样品需带空白样(实验室空白/运输空白)
2. 平行样数量≥10%
3. 加标回收率控制范围:70%~130%
4. 使用有证标准物质进行校准,标准曲线相关系数≥0.995
5. 每20个样品插入质控样(空白加标/基体加标)
1. 样品过滤:使用玻璃纤维滤膜(0.22μm)去除颗粒物
2. 仪器条件优化:毛细管电压(-3500V),脱溶剂气温度(350℃),碰撞能量优化
3. 色谱分离:流动相A为5mmol/L乙酸铵水溶液,B为甲醇,梯度洗脱30min
4. 质谱监测:设置两对特征离子对(定量离子对/定性离子对)
5. 系统适应性:连续进样标准偏差≤15%
1. 特别注意2,4-滴和2,4,5-涕易发生光解,样品需避光保存并在7日内完成分析
2. 高硬度水样可能引发电离抑制,需进行基体效应评估
3. 当样品存在明显杂质干扰时,允许使用固相萃取(SPE)净化
4. 方法验证需满足:定性离子对比例相对偏差≤20%
5. 实验室应监控LC-MS系统污染,每批样品后需运行溶剂空白
以上信息仅供参考,请以相应标准的原文为准!