2种同位素混标/HJ 961-2018/HJ 1026-2019 HJ 961-2018, HJ 1026-2019 Internal Standards Mixture 498 100 µg/mL in Methanol
-
2种同位素混标/HJ 961-2018/HJ 1026-2019|HJ 961-2018, HJ 1026-2019 Internal Standards Mixture 498 HJ 961-2018, HJ 1026-2019 Internal Standards Mixture 498
DRE-A50000498ME | 1ml
-
15种氨基甲酸酯类混标 HJ 961-2018/HJ 1026-2019|HJ 961-2018, HJ 1026-2019 Pesticides Mixture 497 HJ 961-2018, HJ 1026-2019 Pesticides Mixture 497
DRE-A50000497ME | 1ml
-
15种氨基甲酸酯类混标 HJ 961-2018/HJ 1026-2019 HJ 961-2018, HJ 1026-2019 Pesticides Mixture 497 100 µg/mL in Methanol
ZDR-A50000497ME | 1ml
-
5种内标物混标/HJ 646-2013/HJ 805-2016/HJ 950-2018|HJ 646-2013,HJ 805-2016,HJ 950-2018 Internal Standards Mixture 515 HJ 646-2013,HJ 805-2016,HJ 950-2018 Internal Standards Mixture 515
DRE-A50000515DI | 1ml
-
HJ 963-2018&HJ 1023-2019混标套装
1ST020182 | 1mL*4瓶/套
-
5种内标物混标/HJ 646-2013/HJ 805-2016/HJ 950-2018 HJ 646-2013,HJ 805-2016,HJ 950-2018 Internal Standards Mixture 515 2000 µg/mL in Acetone:n-Hexane
ZDR-A50000515DI | 1ml
-
6种内标物混标/HJ 834-2017/HJ 951-2018|HJ 834-2017, HJ 951-2018 VOC & SVOCs internal standards HJ 834-2017, HJ 951-2018 VOC & SVOCs internal standards
DRE-A50000174AI | 1ml
中文名称:2种同位素混标/HJ 961-2018/HJ 1026-2019
英文名称:HJ 961-2018, HJ 1026-2019 Internal Standards Mixture 498 100 µg/mL in Methanol
您正在浏览的产品:2种同位素混标/HJ 961-2018/HJ 1026-2019
手机版:2种同位素混标/HJ 961-2018/HJ 1026-2019
本公司销售的所有产品仅供实验科研使用,不用于人体及临床诊断。
2. 凝胶渗透色谱或固相萃取净化
3. 超高效液相色谱分离(BEH C18色谱柱)
4. 三重四极杆质谱多反应监测模式检测
测定下限:1.2~3.2μg/kg(按取样量10g计)
2. 每20个样品至少分析1个平行样
3. 使用同位素标记内标(如D3-涕灭威砜)进行回收率控制
4. 每批样品需带基体加标样品
2. 加速溶剂萃取:丙酮-二氯甲烷混合溶剂提取
3. 净化:凝胶渗透色谱去除大分子干扰物
4. 浓缩:氮吹至近干后乙腈定容
5. 仪器分析:UPLC-MS/MS检测
2. 涕灭威等部分农药需检测其代谢物
3. 实验过程需避光操作防止光解
4. 使用C18色谱柱时需控制pH在3.0±0.1
2. 吹扫捕集富集目标化合物
3. 热脱附进样
4. 气相色谱分离(DB-624色谱柱)
5. 氢火焰离子化检测器检测
测定下限:0.16mg/kg(按取样量5g计)
2. 每10个样品带1个平行样
3. 使用氘代甲苯作为替代物
4. 每批样品需带基体加标样品
2. 振荡提取后加入纯水稀释
3. 吹扫捕集条件:吹扫温度40℃,吹扫时间11min
4. 色谱条件:程序升温(35℃保持3min,以8℃/min升至120℃)
5. 标准曲线需包含目标碳数范围的化合物
2. 避免使用含石油烃成分的实验耗材
3. 需扣除溶剂峰干扰
4. 高含量样品需稀释后重新测定
以上信息仅供参考,请以相应标准的原文为准!